Maße

The use of Porta doors is recommended in accordance with fire protection requirements of the Polish Building Code on the basis of the Ordinance of the Minister of Inftastructure of 12 April 2002 laying down technical conditions to be complied with by the buildings and their sites
Type of buildingexample of applicationSuggested fire rating or smoke control classDescription (symbol of doors compliant with the requirements)
residential buildings (without fire lobby)entrance doors for flats located in the buildings more than 25 m high (from the the 9th floor up)EI 30
EI 30/S 60 (Sa, Sm)
KWARC (DT-K32/M)
GRANIT typ 2 (DT-PW/II)
hotels, boarding housesentrance doors for flats located in the buildings more than 12 m high (from the 4th floor up)EI 30
EI 30/S 60 (Sa, Sm)
42 dB (DT-AW/M, DT-AW/D)
EI 30 (DT-K32/M, DT-PP-DY)
residential buildingsdoors separating fire areas (buildings without fire lobbies)EI 30 (wys. do 12 m)
EI 60 (wys. pow. 12 m)
EI 30 (DT-K32/M)
EI 60 (DT-PP60)
hotels, boarding houses, public buildingsEI 60 (wysokość budynku do 55 m)EI 60 (DT-PP60)
special applicationsboiler room doorsEI 60EI 60 (DT-PP60)
garage doors (single-family housing excluded)EI 30 (wejście z przedsionka ppoż)
EI 60
EI 30 (DT-K32/M)
EI 60 (DT-PP60)
Note: The Table above shows general fire protection requirements for buildings – the data provided in the Table should be checked and adjusted individually to the given structure.
Recommended use of Porta doors in accordance with the Polish Building Code , depending on the acoustic requirements (acoustic requirements to PN-B-02151:1999)
Type of buildingexample of applicationAcoustic requirementsRecommended by PortaDescription (symbol of doors compliant with the requirements)
Blocks of flatsFlat entrances in the buildings> Rw 27 dBRw 32 dBAGAT, OPAL, KWARC (DT-K32/M) GRANIT typ 1 i 2 (DT-PW/II)
Higher class hotelsdirectly from the vestibule to the roomsAcc. to the designRw 32 dB
Rw 42 dB
42 dB (DT-AW/M,DT-AW/PS, DT-AW/D)
32 dB (DT-A32/M, DT-A32/PS)
EI 30 (DT-K32/M, DT-PP-DY)
From the vestibule to internal vestibule, lobby> Rw 32 dBRw 32 dB32 dB (DT-A32/M, DT-A32/PS)
EI 30 (DT-K32/M, DT-PP-DY)
Lower class hotels, Holiday centresdirectly from the vestibule to the rooms> Rw 32 dBRw 32 dB32 dB (DT-A32/M, DT-A32/PS)
EI 30 (DT-K32/M, DT-PP-DY)
From the vestibule to internal vestibule, lobby> Rw 27 dBRw 27 dB27 dB (DT-A27/M, DT-A27/PS)
hotels, Holiday centresTV, club, conference roomsAcc. to the designRw 42 dB42 dB (DT-AW/M, DT-AW/PS, DT-AW/D)
halls of residence, boarding houses, boarding homes for aged, sanatoriadirectly from the vestibule to the rooms> Rw 32 dBRw 32 dBAGAT, KWARC (Metal door frame)
32 dB (DT-A32/M) (Metal door frame)
EI 30 (DT-K32/M) (Metal door frame)
From the vestibule to internal vestibule, lobby> Rw 27 dBRw 27 dB27 dB (DT-A27/M) (Metal door frame)
TV rooms, reading roomsAcc. to the designRw 42 dB42 dB (DT-AW/M) (Metal door frame)
HospitalsDoctor's surgeriesAcc. to the designRw 42 dB42 dB (DT-AW/M) (Metal door frame)
Doctors' and nurses' roomsAcc. to the designRw 27 dB27 dB (DT-A27/M) (Metal door frame)
Administration and office buildingsWork rooms> Rw 22 dBRw 27 dB27 dB (DT-A27/M, DT-A27/PS)
Rooms for concentrated work> Rw 27 dBRw 32 dB32 dB (DT-A32/M, DT-A32/PS)
EI 30 (DT-K32/M, DT-PP-DY)
Director's offices> Rw 27 dBRw 42 dB42 dB (DT-AW/M, DT-AW/PS, DT-AW/D)
Improved burglar-proof doors
Type of buildingexample of applicationSuggested burglar-proof classDescription (symbol of doors compliant with the requirements)
residential buildingsFlat entrance doorsklasa B
klasa C
OPAL
GRANIT typ 1 i 2 (DT-PW/II)
External doors with low heat transfer coefficient
Type of buildingexample of applicationRequired heat transfer coefficientCoefficient determined for Porta doorsDescription (symbol of doors compliant with the requirements)
Single-family housesBuilding entrance doorsU≤2,6 W/(m2K)U=2,11 W/(m2K)GDAŃSK, TORUŃ, SZCZECIN
Single-family housing and flat blocks, public buildings with low and medium trafficBuilding entrance doorsU≤2,6 W/(m2K)U=1,5 W/(m2K) (Glazed doors)
U=1,6 W/(m2K) (Doors without glazings)
GDYNIA, WROCŁAW (DZ-F)
Alle Rechte vorbehalten